Valco Instruments Co. Inc.
D2-IM.p65
©2011 9/11
Printed in USA
Pulsed Discharge
Detector
Model D-2-IM
Instruction Manual
Valco Instruments Co. Inc.
800
·
367
·
8424 sales
713
·
688
·
9345 tech
713
·
688
·
8106 fax
Valco International
Schenkon, Switzerland
Int + 41
·
41
·
925
·
6200 phone
Int + 41
·
41
·
925
·
6201 fax
Vista de página 0
1 2 3 4 5 6 ... 22 23

Resumo do Conteúdo

Página 1 - Instruction Manual

Valco Instruments Co. Inc.D2-IM.p65©2011 9/11Printed in USAPulsed DischargeDetectorModel D-2-IMInstruction ManualValco Instruments Co. Inc.800 · 367·

Página 2

6IntroductionPDECDPDHIDMODE120160200804024028032036040010245122561286432168421ATTENUATIONDETECTOR TEMP.DISCHARGEZEROV ECDnA HIDPULSED DISCHARGE CONTRO

Página 3 - Table of Contents

7ATTENUATED OUTPUT connectorNormally connected to a strip chart recorder. This output has an unattenuatedrange of 0 - 10V, and an internal signal r

Página 4

8System RequirementsComponents Not Included with the Detector System • Helium (99.999% purity) and other support gases • Ultra high purity grade gas

Página 5 - Introduction

9System RequirementsSpecificationsMains (line): 115/230 V~50/60 Hz, 175 VAFuse: 2 A, time-delay, 5 x 20 mmPressure: 6.9 kPa (1 psi) operating, 6.9 MPa

Página 6 - Safety Notes and Information

10System RequirementsGC Column SelectionTo prevent detector contamination, we stronglyrecommend disconnecting the column from thedetector during colum

Página 7 - Maintenance

11InstallationThe detector is usually mounted on top of the GC column oven. The cabling assupplied requires the discharge module to be located withi

Página 8 - Description of Controls

12Gas ConnectionsRemember these three points discussed earlier: (1) all surfaces that contact thegas stream must be glass or stainless steel; (2) do

Página 9

13CAUTION: Never use leak detecting fluids on any part ofthis system.Installing and Purging the Helium Purifier1. If the pressure regulator has a 1/8

Página 10 - PULSED DISCHARGE CONTROLLER

14Connecting the Discharge Gas to the Detector1. If you are supplying the GC from the helium purifier, use the Valco tee (ZT1).Otherwise, use one of t

Página 11

15InstallationElectrical ConnectionsCAUTION: Do not use a wrench to tighten the SMCconnectors on the bias and electrometer cables.Connections should b

Página 12 - System Requirements

This page intentionally left blank for printing purposes

Página 13 - Purity Specifications

16InstallationInitial Power-Up1. If it is not already there, set the MODE switch on the front of the controller toPDHID.2. Set the discharge gas flow

Página 14 - GC Column Selection

17InstallationFrom this point, the standing current should be observed and logged after anysystem change. In addition, logging the standing current

Página 15 - Installation

18WarrantyThis Limited Warranty gives the Buyer specific legal rights, and a Buyer may alsohave other rights that vary from state to state. For a peri

Página 16 - Gas Connections

19Detector Performance LogIn addition to the occasions indicated in the Comments area of the table below, (see Initial Power-Up, page16), the standing

Página 17

Table of ContentsIntroductionDescription and Operating Principles ...

Página 18 - Testing for Leaks

This page intentionally left blank for printing purposes

Página 19 - Electrical Connections

1IntroductionDescription and Operating PrincipleThe pulsed discharge detector Model D-2-IM is a universal helium photoionizationdetector optimized for

Página 20 - Initial Power-Up

2The PDHID response is universal except for neon, which has an ionization potentialof 21.56 eV. Since this potential is close to the energy of the He

Página 21 - Column Bakeout Precautions

3SafetyThis instrument has been designed and tested in accordance with the productsafety standard, EN61010. It has left the factory in a safe conditi

Página 22 - Warranty

4Components of the Detector SystemComponents of the detector system are listed in Table 1. Check the contents ofthe packages to verify that everythin

Página 23 - Detector Performance Log

5IntroductionTEMPERATURE control and indicatorSets the temperature (°C) of the detector heater block. The indicator is steadily onwhen maximum power