Valco Instruments Co. Inc.
m6-m50.indd
Rev. 2/15
M Series Pump
Models M6 and M50
Instruction Manual
Valco Instruments Co. Inc.
800 · 367· 8424 sales
713
· 688· 9345 tech
713
· 688· 8106 fax
VICI AG International
Schenkon, Switzerland
Int + 41
· 41 · 925· 6200 phone
Int + 41
· 41 · 925· 6201 fax
North America, South America, and Australia/Oceania contact: Europe, Asia, and Africa contact:
®
®
Vista de página 0
1 2 3 4 5 6 ... 33 34

Resumo do Conteúdo

Página 1 - Instruction Manual

Valco Instruments Co. Inc.m6-m50.indd Rev. 2/15 M Series Pump Models M6 and M50 Instruction ManualValco Instruments Co. Inc.800 · 367· 8424 sales 713

Página 2

6Initial SetupM6-LHS Software InstallationInserttheM6-LHSsoftwareCDintothePC.Iftheinstallationdoesn’tbeginautomatically,browsetheCDa

Página 3 - Table of Contents

7Selecting Pump and Gearbox ValuesIntheGearboxpulldownmenu,selectCP-DSM1forModelM6orCP-DSM2forModelM50.InthePumppulldownmenu,selec

Página 4

8 Figure 8: Setting the backlash and volume per revolution valuesCLICKTHEBOXANDENTERTHE µL/REVFROMTHEQCCERTIFICATECLICKTHEBOXANDENTERT

Página 5 - Product Description

9This page is intentionally left blank for printing purposes.

Página 6 - Getting Started

10  Priming and Testing the PumpAt this stage, some basic tests will determine that the tubing connections are tight

Página 7 - 

111. IfthescreeninFigure 9 is not already open, go to the main menu, and choose Utility > Test. 2. IfthetubingIDis0.010”orless,enter

Página 8 - Hardware Installation

12     Figure 10: The Method screenProgramming Application MethodsMethod Screen FunctionsFrom the main menu, choose Meth

Página 9

136: Action line A step in the method sequence, reflecting the values entered by selecting ortypingvaluesinthePump,Valve,andWaitelds.Tomov

Página 10 - Initial Setup

14Example Application MethodsIn the Test Mode, user-entered flow parameters cannot be saved; when you exit the software, the values revert to defaults.

Página 11 - ORCP-DSM2FORMODELM50

158. UsetheDn(down)buttontohighlightthelastline,thenclicktheInsertbutton. 9. Forthenewlyinsertedline,selectDispenseinthepump

Página 12 - CLICKTHEBOXANDENTERTHE

The information in this manual has been carefully checked and believed to be accurate; however, no responsibility is assumed for inaccuracies.VICI mai

Página 13

16 Figure 12:Methodscreen(partial)forexample“DispenseSelectedReagents” method for Model M6Example method 3: “Dispense Selected Reagents”This

Página 14 - Priming and Testing the Pump

17Maintenance Follow these recommended cleaning and maintenance instructions to obtain optimum performance and maximum life from your pump.If the pum

Página 15

18Chemical Compatibility of Wetted SurfacesTo ensure best results, please consider the chemical compatibility of the wetted surfaces with the liquids

Página 16 - Method Screen Functions

19Model M50Valcon H2TheM50capisacarbonber-reinforced,PTFE-lubricatedinertpolymer.Thismaterialisroutinelyusedat5000psiattemperatur

Página 17

20Technical SupportTechnicalsupportforthisproductishandledbytheVICIfacilitiesinHouston,Texas,USA,andSchenkon,Switzerland.USA   

Página 18 - Example Application Methods

21         

Página 19

22Appendix A: MicroLYNX Terminal SectionTerminal Programming Mode Figure 14:MicroLYNX-4commands,partA  

Página 20

23   

Página 21 - Maintenance

247 pin connector Signal     7 pin connector Signal     7 pin connector Signal     

Página 22 - Model M6

25Setting the Address of each MicroLYNXThe party address can be set by either hardware switches or software. In this discussion, “party address” and

Página 23 - Guidelines

Table of ContentsProduct Description Operating Principle...1

Página 24 - Returning Pumps for Repair

26Software method The hardware method is the simplest approach, and should be used when possible.1. Connectthecommunicationscable(RS-232orRS-4

Página 25 - 

27 12. SettheaddresswiththeDNcommand. Input: nDN=“x”[Ctrl-J] The n represents the address assigned by the hardware switches in step 10.

Página 26 - Terminal Programming Mode

28Troubleshooting Party Mode CommunicationsIfyoucan’tcommunicatewithaMicroLYNXinpartymode,rstmakesurethat commands are preceded with the

Página 27

29If problems still exist, perform the following:1. Checkallcableconnectionstoensuretherearenoloosewiresorshortcircuits or incorrect con

Página 28 - Connections

30WarrantyCertain applications using the M Series pump may involve potential risks of death, personal injury, or severe property or environmental dama

Página 29 -   

This page intentionally left blank for printing purposes

Página 30 - VER[Ctrl-J]

1Product DescriptionThe Cheminert® M Series liquid handling pump is a syringe-free pump capable of delivering a bidirectional flow to six orders of ma

Página 31 - Pump Selection Valve

2Getting StartedComponents of the M Series SystemCheck the contents of the packages against Figure 1 to verify that you have received all of the compo

Página 32

3 

Página 33

4Hardware InstallationMountingThe mounting points of the pump motor and controller are given in Figure 2, along with the external dimensions of each m

Página 34 - Warranty

5 

Modelos relacionados M6

Comentários a estes Manuais

Sem comentários